Case Communications 8000 Series Instalační příručka

Procházejte online nebo si stáhněte Instalační příručka pro Sítě Case Communications 8000 Series. Case Communications 8000 Series Installation guide [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 56
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Series 8000 Super Card
Installation Guide
©Case Communications Ltd 1996
X870-300451 Issue 2 0-1 Rev.2
Unit 15, Riverside Business Centre, Victoria Street, High Wycombe, Bucks HP11 2LT
Web: www.casecomms.com Email: [email protected]
Tel (UK): 08700 263 740 Tel (International): +44 (0) 1494 833 740
Fax (UK): 08700 263 741 Fax (International): +44 (0) 1494 833 741
Zobrazit stránku 0
1 2 3 4 5 6 ... 55 56

Shrnutí obsahu

Strany 1 - Installation Guide

Series 8000 Super CardInstallation Guide©Case Communications Ltd 1996X870-300451 Issue 2 0-1 Rev.2 Unit 15, Riverside Business Centre, Victoria Stree

Strany 2 - X870-300451 Issue 2 0-2 Rev.1

X870-300451 Issue 2 1-4 Rev.0

Strany 3 - X870-300451 Issue 2 0-3 Rev.0

2 InstallationThis equipment may only be installed by engineers who are qualified to doso.2.1 Installing the Super CardThe rear of the 8210/8310/8325

Strany 4 - X870-300451 Issue 2 0-4 Rev.1

2.1.2 Pin 1 (Frame Ground) to Signal GroundWhere D-type connectors are provided on the rear panel(s) for V.24 andX.21 interfaces, Pin 1 (Frame Ground

Strany 5 - Contents

2.2 Installing the PIMs on the Super CardEach Super Card carries up to three PIMs which offer a choice of physicalinterface in groups of two ports.

Strany 6 - X870-300451 Issue 2 0-6 Rev.1

2.3 IndicatorsWhen the 8210/8310/8325 unit is powered up, a number of indications aredisplayed on the front display.For the 8310/8325:The green LED b

Strany 7 - 1 The Series 8000 Super Card

2.4 Other EquipmentCheck interfaces between the Super Card and all other equipment which isto be connected (modems, computers, terminals) to ensure c

Strany 8 - 1.2 Physical Description

2.5 Public Digital ServicesFor connection to UK public digital services network termination units(NTUs), please refer to Appendix D, which gives the

Strany 9 - 1.3 PIMs

2.6 Power-Up DiagnosticsThe power-up diagnostics provide a quick self-test facility for the SuperCard. They are executed following a hardware reset.

Strany 10 - X870-300451 Issue 2 1-4 Rev.0

EPROM Checksum TestTo ensure that the correct EPROMs are fitted, and also that they have beenprogrammed correctly, an auto-sizing, Add and XOR checksu

Strany 11 - 2 Installation

read back and compared. This process is repeated with the data inverted.This is then repeated for each location.Action/Possible faultsCheck that the

Strany 12 - X870-300451 Issue 2 2-2 Rev.0

STATUTORY NOTICESAPPROVED for connection totelecommunication systems specifiedin the instructions for use subject tothe conditions set out in them.NS/

Strany 13 - X870-300451 Issue 2 2-3 Rev.0

Action/Possible faultsCheck that all socketed devices are in the correct location andorientation, and that there are no bent pins.X870-300451 Issue 2

Strany 14 - 2.3 Indicators

3 Logging OnYou can control the Super Card either from a local terminal, or over theX.25 network.3.1 LocallyA VT100 compatible terminal is required,

Strany 15 - 2.4 Other Equipment

3.2 From X.25The 'manager' of a Super Card may be accessed remotely from an X.25triple-X PAD. If the X.3 parameters of the remote PAD are

Strany 16 - 2.5 Public Digital Services

Appendix A Specification SummaryPower Supply Obtained from 8210/8310/8325 unitPower Consumption 10 wattsEnvironmentAmbient Temperature Operating:+5°C

Strany 17 - 2.6 Power-Up Diagnostics

X870-300451 Issue 2 A-2 Rev.0

Strany 18 - X870-300451 Issue 2 2-8 Rev.0

Appendix B Interface SpecificationsPIM1 Synchronous V24/RS-232-D DTEPart Number X890-605611Interfaces 2 × 25-way D-type plug (male) DTEControls In CTS

Strany 19 - X870-300451 Issue 2 2-9 Rev.0

PIM2 Synchronous X.21 DTEPart Number X890-605711Interfaces 2 × 15-way D-type plug (male) DTEControls In IndicationControls Out ControlClock Signal Ele

Strany 20 - Action/Possible faults

PIM3 Synchronous V.35 DTEPart Number X890-605811Interfaces 2 × 15-way D-type plug (male) DTEControls In CTS, DCDControls Out RTSClocks RxC, TxC, XTxCC

Strany 21 - 3 Logging On

PIM4 Synchronous X.21 DCEPart Number X890-605911Interfaces 2 × 15-way D-type plug (female) DCEControls In ControlControls Out IndicationClock Signal E

Strany 22 - 3.2 From X.25

PIM5 Synchronous V.24/RS-232-D DCEPart Number X890-607311Interfaces 2 × 25-way D-type plug (female) DCEControls Out CTS, RI, DCD, DSRControls In DRS,

Strany 23 - X870-300451 Issue 2 A-1 Rev.1

PrefaceThis guide provides information for network controllers toinstall Series 8000 Super Cards in the 8210 and 8310 BasicUnits and the 8325 Compact

Strany 24 - X870-300451 Issue 2 A-2 Rev.0

PIM6 port a Synchronous X.21 DTEPart Number X890-607211Interface 15-way D-type plug (male) DTEControls In IndicationControls Out ControlClock Signal E

Strany 25 - X870-300451 Issue 2 B-1 Rev.0

PIM6 port b Synchronous X.21 DCEPart Number X890-607211Interface 15-way D-type plug (female) DCEControls In ControlControls Out IndicationClock Signal

Strany 26 - X870-300451 Issue 2 B-2 Rev.0

PIM7 port a Synchronous X.21 DTEPart Number X890-607111Interface 15-way D-type plug (male) DTEControls In IndicationControls Out ControlClock Signal E

Strany 27 - X870-300451 Issue 2 B-3 Rev.0

PIM7 port b Synchronous V.24/RS-232-D DTEPart Number X890-607111Interface 25-way D-type plug (male) DTEControls In CTS, RI, DCD, DSRControls Out DRS,

Strany 28 - X870-300451 Issue 2 B-4 Rev.0

X870-300451 Issue 2 B-10 Rev.0

Strany 29 - X870-300451 Issue 2 B-5 Rev.0

Appendix C CablesThis appendix gives the part number and pinout for all available standardcables.Refer to the Series 8000 Xpress PSE User Guide for V.

Strany 30 - X870-300451 Issue 2 B-6 Rev.0

Table C-3 V.35 CablesPIMTYPEPIMINTERFACETYPEREMOTEINTERFACETYPELENGTHPARTNUMBERPINOUTDIAGRAMPIM3PIM3PIM3PIM3DTEDTEDTEDTEDCEDCEDTEDTE3M5M3M5MX890-4034

Strany 31 - X870-300451 Issue 2 B-7 Rev.0

Figure C-1 V.24 DCE Cables X890-403111 and X890-4086111TxD 2RxD 3RTS 4CTS 5DSR 6SG 7DCD 891011121314TxC 1516RxC 171819DTR 2021RI 2223XTxC 24BO 2512 T

Strany 32 - X870-300451 Issue 2 B-8 Rev.0

Figure C-2 V.24 DTE Cables X890-403011 and X890-4087111TxD 2RxD 3RTS 4CTS 5DSR 6SG 7DCD 891011121314TxC 1516RxC 171819DTR 2021RI 2223XTxC 24BO 2512 T

Strany 33 - X870-300451 Issue 2 B-9 Rev.1

Figure C-3 V.54 DCE Cable X890-4063111TxD 2RxD 3RTS 4CTS 5DSR 6SG 7DCD 891011121314TxC 1516RxC 171819DTR 2021RI 22DRS 23XTxC 24BO 2512 TxD3 RxD4 RTS5

Strany 34

MORE STATUTORY NOTICESCase Communications Ltd declare that this product conforms with the protection requirements ofCouncil Directive 89/336/EEC on th

Strany 35 - Appendix C Cables

Figure C-4 X.21 Cables X890-401011 and X890-40881115-Way D-TypePlug15-Way D-TypeSocketC(A)C(B)S(A)S(B)T(A)T(B)R(A)R(B)I(A)I(B)SGND310613294115128C(A)

Strany 36 - Table C-4 V.36 Cables

Figure C-5 V.35 DCE Cables X890-403411 and X890-409411MRACPlug15-Way D-TypeSocketYAAVXRTPSBCHDFUWTxC(A)TxC(B)RxC(A)RxC(B)RXD(A)RXD(B)TXD(A)TXD(B)SGND

Strany 37

Figure C-6 V.35 DTE Cables X890-403311 and X890-409511MRACSocket15-Way D-TypeSocketUWPSRTBFEHCDVYXAATxCE(A)TxCE(B)TxD(A)TxD(B)RxD(A)RxD(B)SGNDDCDDSRD

Strany 38

Figure C-7 V.36 DCE Cables X890-406611 and X890-409011TxD(A)TxD(B)RTS(A)RTS(B)RxD(A)RXD(B)DCD(A)DCD(B)TxC(A)TxC(B)RxC(A)RxC(B)SGND37-Way D-TypePlug15

Strany 39

Figure C-8 V.36 DTE Cables X890-406711 and X890-40911137-Way D-TypeSocket15-Way D-TypePlug42272562413315238261937TxD(A)TxD(B)RTS(A)RTS(B)RxD(A)RxD(B)

Strany 40

Figure C-9 V.24 to DIN 'Alarm & Diagnostic' Cable X870-401511PROT GND 1TxD 2RxD 3Relay + 4Relay + 5Relay – 6SGND 7Relay – 81 PROT GND

Strany 41

X870-300451 Issue 2 C-12 Rev.0

Strany 42

Appendix D UK PSS and KiloStreamD.1 GeneralPorts labelled ''SAFETY WARNING See Instructions For Use'' do notprovide isolation suf

Strany 43

If any connections on a Super Card are connected to PSS or KiloStreamthen all other connections on that Super Card must be to apparatus thathas either

Strany 44

D.2 NET1 ConsiderationsThe X.21 interfaces on Super Card do not provide 'DTE Uncontrolled NOTREADY'.V.24, X.21 and V.35 interfaces are appr

Strany 45

Contents1 The Series 8000 Super Card 1-11.1 Introduction 1-11.2 Physical Description 1-21.3 PIMs 1-32 Installation 2-12.1 Installing the Super Card 2-

Strany 46

D.3 NTU Pin AssignmentsTables D-2 to D-4 show the V.24, X.21 and V.35 interface pin assignmentspresented to a PSS/KiloStream NTU at the NTU end of th

Strany 47 - D.1 General

Table D-4 V.35 Interface Pin Assignments(At NTU End of Cable X818-401311)PIN NO. DIRECTION ASSIGNMENTYAAVXRTPSBC/HDFInputInputInputInputInputInputOut

Strany 48 - X870-300451 Issue 2 D-2 Rev.0

D.4 Cable PinoutsFigures D-1 to D-3 give the pinouts of the three PSS/KiloStream cableslisted in Table D-1.Figure D-1 V.24 PSS/KiloStream Cable Part

Strany 49 - D.2 NET1 Considerations

Figure D-2 X.21 PSS/KiloStream Cable Part Number X890-40841115-Way D-TypePlug15-Way D-TypeSocketC(A)C(B)S(A)S(B)T(A)T(B)R(A)R(B)I(A)I(B)SGND310613294

Strany 50 - D.3 NTU Pin Assignments

Figure D-3 V.35 PSS/KiloStream Cable Part Number X818-401311MRACPlug15-Way D-TypeSocket (tooled)YAAVXRTPSBCHDFTxC(A)TxC(B)RxC(A)RxC(B)RxD(A)RxD(B)TxD

Strany 51

Figure D-4 V.36 PSS/KiloStream Cable Part Number X890-406611TxD(A)TxD(B)RTS(A)RTS(B)RxD(A)RXD(B)DCD(A)DCD(B)TxC(A)TxC(B)RxC(A)RxC(B)SGND37-Way D-Type

Strany 52 - D.4 Cable Pinouts

X870-300451 Issue 2 D-10 Rev.0

Strany 53

Figures1-1 Super Card 1-21-2 Super Card Rear Panel 1-2C-1 V.24 DCE Cables X890-403111 and X890-408611 C-3C-2 V.24 DTE Cables X890-403011 and X890-4087

Strany 54

1 The Series 8000 Super Card1.1 IntroductionThe Series 8000 Super Card is a multi-purpose processor that plugs intothe Cray 8210 and 8310 Basic Units

Strany 55

1.2 Physical DescriptionThe Super Card, part number X870-603411, is illustrated in Figure 1-1.Figure 1-1 Super CardPIMXPIMYPIMZDiagnostic/Manager Po

Strany 56

1.3 PIMsAs described in Section 1.2, each Super Card can carry up to three PIMs,each of which provides the interface circuitry and physical connector